TOPIC: water heater releif pipe?

water heater releif pipe? 15 years 2 months ago #20455

Hello, everone.
Attached picture is water heater that I recently inspected.
The water heater releif pipe is terminated to under crawl space.
Do I have to need somthing comment for that?
Attachments:

Please Log in to join the conversation.

Re: water heater releif pipe? 15 years 2 months ago #20469

  • Ian Niquette
  • Ian Niquette's Avatar
  • Offline
  • Platinum Member
  • Platinum Member
  • Just another goofy lookin guy with no hair!!
  • Posts: 1355
  • Thank you received: 0
Kyu, in the few crawlspaces that I see, this has been a common set up. I wouldn't make a huge deal of it, as it is not a continuos drain. They will have the issue of not knowing if the valve becomes corroded and starts to push open , however. In this case, moisture will be distributed into the crawlspace. They will have to monitor this closely. It is a pain in the butt, but not much will be done to correct it. Just make them aware, that they need to monitor it, and your job is complete.

Please Log in to join the conversation.

Square One Home Inspection
Square One Home Inspection proudly serves Green Lake, Fond du Lac, Dodge, Marquette, Columbia, Winnebago, and Waushara Counties. Complete home inspections, thermal imaging and Radon testing available.
www.squareonehomeinspection.com
Keywords : Fond du Lac Home Inspection,...
Last Edit: by Ian Niquette.

Re: water heater releif pipe? 15 years 2 months ago #20478

  • Tim
  • Tim's Avatar
  • Offline
  • Elite Member
  • Elite Member
  • Posts: 208
  • Thank you received: 0

Hello, everone.
Attached picture is water heater that I recently inspected.
The water heater releif pipe is terminated to under crawl space.
Do I have to need somthing comment for that?

The Temperature Pressure Relief drain should terminate above the floor, not in the crawl space
This link, may help you out, www.factsfacts.com/MyHomeRepair/PressureRelief.htm

Good luck
Tim
Attachments:

Please Log in to join the conversation.

link: www.timshomeinspections.com/
page title:TIMS HOME INSPECTIONS
description: Maryland Home Inspector providing inspection services in western Maryland, and the surrounding ares which include Washington, Frederick, Allegheny counties and some areas of Pennsylvania
keywords:licensed home...

Re: water heater releif pipe? 15 years 2 months ago #20552

Nice picture Tim. Terminating it above and then having it drain looks like a much better solution as you can see when it's discharging.

Please Log in to join the conversation.

Dominic Maricic
Home Inspector Pro Home Inspection Software - CEO

Re: water heater releif pipe? 15 years 2 months ago #20558

  • Tim
  • Tim's Avatar
  • Offline
  • Elite Member
  • Elite Member
  • Posts: 208
  • Thank you received: 0

Nice picture Tim. Terminating it above and then having it drain looks like a much better solution as you can see when it's discharging.


In this set up the drain terminates in the garage, so that if there is a problem, the HO knows very soon

Please Log in to join the conversation.

link: www.timshomeinspections.com/
page title:TIMS HOME INSPECTIONS
description: Maryland Home Inspector providing inspection services in western Maryland, and the surrounding ares which include Washington, Frederick, Allegheny counties and some areas of Pennsylvania
keywords:licensed home...

Re: water heater releif pipe? 15 years 2 months ago #20584

Thanks for all of your opinions.
I understand that the situation should be noted whatever depending on inspector's experience.
Your opinions are very helpfull for me.

Thanks again..

Please Log in to join the conversation.