• 888-750-4777
  • This email address is being protected from spambots. You need JavaScript enabled to view it.
Welcome, Guest
Username: Password: Remember me
  • Page:
  • 1
  • 2

TOPIC: Automated Breaker Shut Off System?

Automated Breaker Shut Off System? 15 years 1 month ago #23267

I just love this stuff.  Every time I think I've seen it all....
Attachments:

Please Log in to join the conversation.

URL : www.progressiveinspection.com
Title: Irvine Home Inspector
Description: Providing home inspections in California, including: Dana Point, Laguna Niguel, Mission Viejo, San Clemente, Irvine, Aliso Viejo, Temecula, Corona, Laguna Niguel, Rancho Santa Margarita, Laguna Woods
Keywords: Dana...
Last Edit: by Will Handley.

Re: Automated Breaker Shut Off System? 15 years 1 month ago #23268

That's quite a difficult spot to get into when a breaker trips!

Please Log in to join the conversation.

Dominic Maricic
Home Inspector Pro Home Inspection Software - CEO

Re: Automated Breaker Shut Off System? 15 years 1 month ago #23273

  • Ian Niquette
  • Ian Niquette's Avatar
  • Offline
  • Platinum Member
  • Platinum Member
  • Just another goofy lookin guy with no hair!!
  • Posts: 1355
  • Thank you received: 0
Nice, I love it when the home owner has to get the aluminum ladder out to throw the juice to the panel in the garage. And talk about spacious. How much clearance is there in the front? 5 to 10 inches?

Please Log in to join the conversation.

Square One Home Inspection
Square One Home Inspection proudly serves Green Lake, Fond du Lac, Dodge, Marquette, Columbia, Winnebago, and Waushara Counties. Complete home inspections, thermal imaging and Radon testing available.
www.squareonehomeinspection.com
Keywords : Fond du Lac Home Inspection,...

Re: Automated Breaker Shut Off System? 15 years 1 month ago #23275

2.5" clearance.  When I went into the garage it was dark, I looked to see if the front of the door was clear, but not the track on that side.  As the door opened from the far side of the garage it looked as though contact would occur.  The tenants told use they use to hang clothes on the track to dry, but when the kids closed the door it shut the breakers off when traveling by.

Substandard clearance at 2.5", height at almost 7' above floor, circuits not labeled, exposed 120v wiring, possible damage from adjacent mechanical equipment, compromised fire wall, "Zinsco" equipment and this ended up being a bootlegged sub panel supplied from another original "Zinsco" 50 amp panel at the rear exterior wall of the structure.

Call "Sparky" pronto....

Please Log in to join the conversation.

URL : www.progressiveinspection.com
Title: Irvine Home Inspector
Description: Providing home inspections in California, including: Dana Point, Laguna Niguel, Mission Viejo, San Clemente, Irvine, Aliso Viejo, Temecula, Corona, Laguna Niguel, Rancho Santa Margarita, Laguna Woods
Keywords: Dana...
Last Edit: by Will Handley.

Re: Automated Breaker Shut Off System? 15 years 1 month ago #23276

  • Ian Niquette
  • Ian Niquette's Avatar
  • Offline
  • Platinum Member
  • Platinum Member
  • Just another goofy lookin guy with no hair!!
  • Posts: 1355
  • Thank you received: 0
So what was your wording on this situation, if I may ask?

Please Log in to join the conversation.

Square One Home Inspection
Square One Home Inspection proudly serves Green Lake, Fond du Lac, Dodge, Marquette, Columbia, Winnebago, and Waushara Counties. Complete home inspections, thermal imaging and Radon testing available.
www.squareonehomeinspection.com
Keywords : Fond du Lac Home Inspection,...

Re: Automated Breaker Shut Off System? 15 years 1 month ago #23277

29. Zinsco electrical panels and or equipment are present and in use at time of inspection:
a. Zinsco electrical equipment is known to present an unsafe condition with regard to electrocution and or fire safety issues.
b. We did not remove the dead front covers for fear of damage to the equipment.
c. Circuits are not clearly and or accurately labeled, (Unsafe Condition).
d. Existing 50 amp service is considered insufficient for the existing structure size, use and load demand requirements.
e. 100 amp service is minimum recommended standard.
f. Refer to the following internet links for additional information regarding improved electrical safety in older homes.
g. www.inspect-ny.com/electric/Zinsco.htm
h. www.cpsc.gov/CPSCPUB/PUBS/524.html
i. www.cpsc.gov/CPSCPUB/PUBS/afci.html
30. Substandard installation of the garage sub panel directly adjacent to the roll up garage door framing, (Unsafe Condition):
a. Restricted access, (Unsafe Condition).
b. Equipment is subject to physical damage, (Unsafe Condition).
c. Equipment is elevated more than 6’ above the floor, (Unsafe Condition).
d. Exposed 120v wiring noted off same, (Unsafe Condition).

Please Log in to join the conversation.

URL : www.progressiveinspection.com
Title: Irvine Home Inspector
Description: Providing home inspections in California, including: Dana Point, Laguna Niguel, Mission Viejo, San Clemente, Irvine, Aliso Viejo, Temecula, Corona, Laguna Niguel, Rancho Santa Margarita, Laguna Woods
Keywords: Dana...
  • Page:
  • 1
  • 2
Time to create page: 0.193 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.