Technical name 14 years 6 months ago #22051

I know this is to stop rafter spread, but I can't remember the name for these. It is in a garage, the first 2 rafters only.
Attachments:

Please Log in to join the conversation.

<b>Title:</b> Orland Park Home Inspector
www.OrlandParkHomeInspections.com
<b>Des:</b> Orland Park Home inspector performs home inspections in Orland Park, Tinley Park, New Lenox, Frankfort, & Palos Heights. 708-535-6057, 708-612-6679
<b>UPath:</b>...

Re: Technical name 14 years 6 months ago #22065

Would cable tie downs be appropriate?

Please Log in to join the conversation.

Home Safe Home Inspections
Link Url: Cleveland Home Inspector - www.hshinspections.net/
Body:Performing Home Inspections in Cleveland, Parma, Brecksville, Broadview Heights, North Royalton, Strongsville and surrounding areas.
Keywords:Parma,Broadview...

Re: Technical name 14 years 4 months ago #24604

Because they're made from cable, I guess I agree with David and would call thhem collar ties. If they were made of wood... and what should be there instead of the retro fitted cable ties are called "collar ties."

Please Log in to join the conversation.

Comprehensive Home & Building Inspections
www.homeinspectionsnewyork.com
URL:Comprehensive-Home-Building-EIFS-Inspections

Certified EIFS Inspector
www.eifsinspectionsnewyork.com
URL:Comprehensive-EIFS-Home-Building-Inspections

Staten Island, Brooklyn, Queens, Manhattan, Bronx, Long Island

Re: Technical name 14 years 4 months ago #24638

I have heard them called "metal straps," and "coil straps," ostensibly to prevent the bottoms of the rafters from spreading outward.  A collar tie should be up withing 4' of the apex of the roof, intending to keep the roof from spreading upward or outward.  If they are near the middle of the rafter they become unstable. 

Two problems with this post-facto strap application that is pictured above:  they can be tightened too much and force the roof upward (!) and do not have much wind load resistance.

Were they on the edge or in the center of the garage?  Maybe someone removed the original truss structure because they wanted a storage loft or something?  Depending on what the guy wanted to do, perhaps to prevent sagging in the middle of the roof at those rafter points, a scissor truss may have been a better installation.

Please Log in to join the conversation.

Jay Markanich Real Estate Inspections, LLC
Based in Bristow, serving all of Northern Virginia
www.jaymarinspect.com
Northern Virginia Home Inspector
Festina Lente - Make Haste Slowly

Re: Technical name 14 years 4 months ago #24641

Jay is right, a coller tie is located closer to the apex. It would be a ceiling joist

Please Log in to join the conversation.

Comprehensive Home & Building Inspections
www.homeinspectionsnewyork.com
URL:Comprehensive-Home-Building-EIFS-Inspections

Certified EIFS Inspector
www.eifsinspectionsnewyork.com
URL:Comprehensive-EIFS-Home-Building-Inspections

Staten Island, Brooklyn, Queens, Manhattan, Bronx, Long Island

Re: Technical name 14 years 3 months ago #24867

I saw that pic on the Nachi Board.
I think my response was that this garage, shed or what not, is old, has a low pitched roof, and they used an oversized 1/2"+/- steel cable to pull it back together. Probably no rafter ties or collar ties.
That cable is oversized for those puney turn buckles with open ends on them and whoever installed those cable clamps had no idea the amount of tension there was going to be.
The cable clamps are backwards,  you never saddle a dead horse on a steel cable.
It would be my guess that the weight of the cable is doing the job of acting as the rafter tie.  :) ;)

Please Log in to join the conversation.

Cyr Home & Commercial Property Inspections
body text: Home and commercial property inspections across Maine, Kennebec county and all of Central Maine.
Keywords: Central Maine Home Inspectors, home inspector, commercial inspections
Meta tags:Serving all of Central Maine and surrounding areas
URL:...
  • Page:
  • 1
  • 2
Time to create page: 0.185 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.