TOPIC: Poll: Question of the day/week

Poll: Question of the day/week 13 years 10 months ago #37867

Topic of discussion - Plumbing, water heater, pressure relief extension

Note how you would report on the following pictures. There can be more than one answer.

Q. do you like this format? Can we have a seperate thread called picture of the day/week?

I want report verbiage from inspectors, why an issue, recommendations.

Tank is conventional, gas fuel source, located in basement and there is a floor drain.

Suggestions appreciated!!

Attachments:

Please Log in to join the conversation.

Home Safe Home Inspections
Link Url: Cleveland Home Inspector - www.hshinspections.net/
Body:Performing Home Inspections in Cleveland, Parma, Brecksville, Broadview Heights, North Royalton, Strongsville and surrounding areas.
Keywords:Parma,Broadview...
Last Edit: by David Macy.

Re: Poll: Question of the day/week 13 years 10 months ago #37876

Weeping TPR Valve, recommend evaluation by a Plumber.

Improper TPR Piping Material, recommend Evaluation by a Plumber with remedy as necessary.

Please Log in to join the conversation.

Re: Poll: Question of the day/week 13 years 10 months ago #37877

I see the pipe is rated for use with a TPR valve so I would state.

Water Heater TPR valve leaking Recommend a Licensed and certified Plumber inspect and make any repairs needed .

However since you are trying to be tricky by showing the label on the valve is rated 500,000 btu max and the PVC shows 1000,000 btu max....well? ;D

Please Log in to join the conversation.

Last Edit: by Bob Elliott.

Re: Poll: Question of the day/week 13 years 10 months ago #37886

Actually Bob I was not sure about the BTU ratings of the relief valve. One of the reasons I posted.

Would not the plastic discharge need to be rated for the relief valve.

The water discharging is a no brainer.

I often see plastic piping at the blow tube and often wonder if it is a rated material.

I also liked the question of the day as it helps me learn.

I am not qualified to be the poster and would leave to more qualified inspectors.

I would also encourge new inspectors to answer the posts as it is a good way to learn, no one will be deaming here and if they are Dom will kick your butt!!

Please Log in to join the conversation.

Home Safe Home Inspections
Link Url: Cleveland Home Inspector - www.hshinspections.net/
Body:Performing Home Inspections in Cleveland, Parma, Brecksville, Broadview Heights, North Royalton, Strongsville and surrounding areas.
Keywords:Parma,Broadview...
Last Edit: by David Macy.

Re: Poll: Question of the day/week 13 years 10 months ago #37888

I tried the same thing on active rain with. a forum

Please Log in to join the conversation.

Re: Poll: Question of the day/week 13 years 10 months ago #37889

Bob I noticed your location is Mars, that is funny!!

I am nmot sure what you mean about the active rain.

Please Log in to join the conversation.

Home Safe Home Inspections
Link Url: Cleveland Home Inspector - www.hshinspections.net/
Body:Performing Home Inspections in Cleveland, Parma, Brecksville, Broadview Heights, North Royalton, Strongsville and surrounding areas.
Keywords:Parma,Broadview...
  • Page:
  • 1
  • 2
Time to create page: 0.216 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.