Code questions - Card 1 14 years 4 months ago #34633

I know we do not inspect to code, but I believe having a good grasp of the code is essential to being a good home inspector.

So I am going to do some posts to find out how much we know, remember, or have forgotten. ;)

#1 The studs used in wood foundation wall shall be _____-inch by _____-inch members.

#2 Anchor bolts shall be at least _____ inch in diameter and shall extend a minimum of _____ inches into masonry or concrete.

#3 Anchor bolts shall be spaced a maximum of _____ feet on center and no further than _____ inches from each corner.

#4 The grade away from foundation wall shall fall a minimum of _____ inches within the first _____ feet.

#5 Wood sill plates shall be a minimum of _____-inch by _____-inch nominal lumber.

Please Log in to join the conversation.

Virginia Beach Home Inspector
Last Edit: by Troy Pappas.

Re: Code questions - Card 1 14 years 4 months ago #34635

  • Bert de Haan
  • Bert de Haan's Avatar
  • Offline
  • Platinum Member
  • Platinum Member
  • If it is worth doing, it's worth doing well.
  • Posts: 741
  • Thank you received: 0
#1. Not sure about the wood foundation but I think 2x4 at 12" O/C
#2. 1/2" diameter and stick above the foundation enough to get a nut on ;)
#3. 48" O/C no further from the corner than 12" (or is it 6"?)
#4. Grade should be sloping enough to be visible.  (I don't think an amount is specified in the Ontario B.C.
#5. Sill plates 2x4.

Please Log in to join the conversation.

Bert de Haan
www.KitchenerWaterlooHomeInspector.ca
Benchmark Home Inspection Services Kitchener-Wateroo and Guelph area Home Inspection
Serving Kitchener-Waterloo, Guelph, Orangeville, Mount Forest and surrounding areas.
Keywords: Kitchener-Waterloo home inspector, Guelph home inspection,...

Re: Code questions - Card 1 14 years 4 months ago #34636

#1 The studs used in wood foundation wall shall be _2____-inch by _6____-inch members.

#2 Anchor bolts shall be at least _____ inch in diameter and shall extend a minimum of __7___ inches into masonry or concrete.

#3 Anchor bolts shall be spaced a maximum of __6___ feet on center and no further than _12____ inches from each corner.

#4 The grade away from foundation wall shall fall a minimum of _6____ inches within the first _10____ feet.

#5 Wood sill plates shall be a minimum of _____-inch by _____-inch nominal lumber.

Here is a good link for a code quiz.

http://www.bookmarki.com/Articles.asp?ID=208

Please Log in to join the conversation.

Home Safe Home Inspections
Link Url: Cleveland Home Inspector - www.hshinspections.net/
Body:Performing Home Inspections in Cleveland, Parma, Brecksville, Broadview Heights, North Royalton, Strongsville and surrounding areas.
Keywords:Parma,Broadview...

Re: Code questions - Card 1 14 years 4 months ago #34637

  • Bert de Haan
  • Bert de Haan's Avatar
  • Offline
  • Platinum Member
  • Platinum Member
  • If it is worth doing, it's worth doing well.
  • Posts: 741
  • Thank you received: 0
When you wrote 6' O/C for anchor bolts my curiosity was piqued.  Almost every plan here has 4' o/c specified so I checked the OBC.  (Ontario Building Code.)   
The OBC says 7'-10" o/c with minimum 4" embedded. 
Having a building code quiz is difficult when we are dealing with different codes.
Maybe a best practices quiz would be a possibility. 

Please Log in to join the conversation.

Bert de Haan
www.KitchenerWaterlooHomeInspector.ca
Benchmark Home Inspection Services Kitchener-Wateroo and Guelph area Home Inspection
Serving Kitchener-Waterloo, Guelph, Orangeville, Mount Forest and surrounding areas.
Keywords: Kitchener-Waterloo home inspector, Guelph home inspection,...

Re: Code questions - Card 1 14 years 4 months ago #34659

These questions refer to the ICC. (2006)

7inch minimum into masonry, at least 1/2 diameter, maximum 6ft on center.

Great link David, thanks.

Please Log in to join the conversation.

Virginia Beach Home Inspector

Re: Code questions - Card 1 14 years 4 months ago #34678

#1 - today was the first time in years I saw anchor bolts in a pre-drywall inspection.  For me it has always been straps and they are buried 9" into the wall.
#2 - Don't see'em enough to know!
#3 - See'em #2...
#4 - The rear of my house, on grade, is dead level in its slope away from the house!
#5 - 2x4 and pressure treated.  What is "nominal" wood?

Please Log in to join the conversation.

Jay Markanich Real Estate Inspections, LLC
Based in Bristow, serving all of Northern Virginia
www.jaymarinspect.com
Northern Virginia Home Inspector
Festina Lente - Make Haste Slowly
Last Edit: by Jay Markanich.