• 888-750-4777
  • This email address is being protected from spambots. You need JavaScript enabled to view it.
Welcome, Guest
Username: Password: Remember me
  • Page:
  • 1

TOPIC: Flex line

Flex line 14 years 2 months ago #36117

I know flex line has to be all the way in or all the way out of the heating cabinet.  I'm wondering if flex line in required at all?  Could a furnace be piped only using solid piping?

Please Log in to join the conversation.

Re: Flex line 14 years 2 months ago #36129

If flex line is used I would check with the manufacturers recommendations for installing.

Most of the furnaces I see are hard piped. My furnace is hard piped.

Please Log in to join the conversation.

Home Safe Home Inspections
Link Url: Cleveland Home Inspector - www.hshinspections.net/
Body:Performing Home Inspections in Cleveland, Parma, Brecksville, Broadview Heights, North Royalton, Strongsville and surrounding areas.
Keywords:Parma,Broadview...

Re: Flex line 14 years 2 months ago #36140

I know flex line has to be all the way in or all the way out of the heating cabinet.  I'm wondering if flex line in required at all?  Could a furnace be piped only using solid piping?


Not sure where you operate but flex line thru a cabinet is NOT allowed.  Must be rigid pipe through cabinet enclosures. 

All rigid is just fine in my area.  Sismeic areas often require flex line up to the cabinet to allow the cabinet to rock and roll during a quake without breaking the gas line. 

Please Log in to join the conversation.

Bruce Ramsey, ACI
  • Page:
  • 1
Time to create page: 0.171 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.