Re: Buried Romex wire 11 years 9 months ago #52147

I wouldn't call it harassing.  He was correct.  Many inspectors call NM conductors Romex and are usually incorrect.  Romex brand is more expensive than the stuff that Home Depot and Lowes sells.  If you want to make a statement, make sure it is correct.  If you state Romex, make sure it is, otherwise use the generic NM cable.  If you state it is a Jacuzzi tub, make sure it is.  If you have ever priced the difference between a spa tub and a Jacuzzi spa tub, you will understand.  The same goes for using Formica in place of laminate.  Be precise and the issues disappear.

Romex does make a  UF-B Direct Burial conductor.  Marked as such. 

Please Log in to join the conversation.

There is nothing sweeter than the smell of fresh cut grass on a baseball infield, the click of a wooden bat and the taste of a hot dog at a warm sunny daytime double-header.

Re: Buried Romex wire 11 years 9 months ago #52150

You wont find Romex in the homes of 9 million people surrounding Chicago. Not allowed
Attachments:

Please Log in to join the conversation.

Dan Musielski
Inspector/Engineer
Assured Home Inspections; Batavia, IL
www.InspectThatHouse.com

See us in the Fox News Channel! FOX NEWS Shattered Dreams
www.foxnews.com/us/2010/10/13/foreclosur...ickens-experts-fear/

Re: Buried Romex wire 11 years 9 months ago #52154

Romex is not allowed in buildings over 3 floors tall either.

a few other things:
A minimum of 1/4 inch of it cable insulation must be inserted into the box.
Must be protected from physical damage if outside of the finished wall.
And helped plate is required if the cable is within 1 1/4 inch of the stud face.
The cable must be clamped to the junction box with an improved clamp or secured within 8 inches of a plastic box.
No sharp bends allowed.
Conductor must be secured at least every 4 1/2 feet.
Must be protected within 6 feet of an attic access opening.
Cannot be used below floor joists if less than #8/3 wire.
18 in.? boxes too small for (3X) 12/2 Romex/NM cable

Please Log in to join the conversation.

Home Inspector
HVAC Systems Design
ITC Level III Thermography - Building Science Thermographer
Thermal Imaging
Serving Clarksville - Nashville TN and the Mid TN area
www.MidTnInspections.com
www.ThermalImagingScan.com
To link to my pages:
www.midtninspections.com/link-submission

Re: Buried Romex wire 11 years 9 months ago #52184

That's really interesting Dan. Did all areas East of that line ban it, or just Chicago?

Please Log in to join the conversation.

Dominic Maricic
Home Inspector Pro Home Inspection Software - CEO

Re: Buried Romex wire 11 years 9 months ago #52194

Hi Dominic...East of the line is Dupage & Cook county which is Chicago and most of the surrounding suburbs. Romex has never been used or allowed; it's always been pipe and wire. If you go into Home Depot it's not even sold.  West of the line is converting more and more to pipe and wire.  Don't dare use a plastic box until your into farmland or Iowa!

Please Log in to join the conversation.

Dan Musielski
Inspector/Engineer
Assured Home Inspections; Batavia, IL
www.InspectThatHouse.com

See us in the Fox News Channel! FOX NEWS Shattered Dreams
www.foxnews.com/us/2010/10/13/foreclosur...ickens-experts-fear/

Re: Buried Romex wire 11 years 9 months ago #52200

Ahhh, the "Chicago Machine"! What will ever happen to Chicago when the Unions eventually die off?

Please Log in to join the conversation.

Jeffrey R. Jonas
507.213.7468
This email address is being protected from spambots. You need JavaScript enabled to view it.

FB: www.facebook.com/MN.Home.Inspector

www.JRJConsultants.net
www.OwatonnaHomeInspector.com
www.MinnesotaCommercialBuildingInspections.com

URL: www.owatonnahomeinspector.com
Title: Critical Eye Property Inspections
Description: Providing...
Time to create page: 0.262 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.