TOPIC: aluminume wires

aluminume wires 14 years 8 months ago #30497

I just inspected a house built in about 1981.  Almost all the wires were copper except for the two circuits that control the heater and range.  They appeared to have aluminume wiring.  Other then calling it out as aluminume is there anything else I should do?
Attachments:

Please Log in to join the conversation.

Goal Line Inspections
fielding your inspection needs
www.goallineinspections.com
Serving: Portland, Gresham, Beaverton and the greater Portland metro area

Re: aluminume wires 14 years 8 months ago #30498

  • Bill Warner
  • Bill Warner's Avatar
  • Offline
  • Elite Member
  • Elite Member
  • There's a fine line between comedy and humor...
  • Posts: 269
  • Karma: 1
  • Thank you received: 1
Multi-strand aluminum has no concerns and is common on those appliances.

It's solid strand aluminum which is problematic and should be called out for further evaluation.

Your picture shows multistrand and is not an issue.

Please Log in to join the conversation.

Bill Warner
Dayton Infrared Thermal Inspection
DaytonThermalInspection.com
Infrared Thermal Imaging Inspections Serving Dayton, Cincinnati, and Greenville Ohio
For a Link Exchange please This email address is being protected from spambots. You need JavaScript enabled to view it. your info

Re: aluminume wires 14 years 8 months ago #30499

Great thanks for the info

Please Log in to join the conversation.

Goal Line Inspections
fielding your inspection needs
www.goallineinspections.com
Serving: Portland, Gresham, Beaverton and the greater Portland metro area

Re: aluminume wires 14 years 8 months ago #30869

Most large appliances use multi-strand aluminum.  Don't look now, but the service conductors are aluminum too.  Did they use jelly at the connection lugs?

Please Log in to join the conversation.

Jay Markanich Real Estate Inspections, LLC
Based in Bristow, serving all of Northern Virginia
www.jaymarinspect.com
Northern Virginia Home Inspector
Festina Lente - Make Haste Slowly

Re: aluminume wires 14 years 5 months ago #33556

The 110 or 120 is what the problem is with the 220 and 240 wiring is Okay.



www.thegreenvillehomeinspector.com
www.thecolumbiahomeinspector.com
www.bestcharlottehomerepairs.com

Please Log in to join the conversation.

The Charlotte Home Inspector
www.thecharlottehomeinspectors.com
Home inspections in Charlotte, Monroe, Mooresville, Gastonia, and Concord.
Meta Key: Charlotte Home Inspection, Mooresville Home Inspector, home inspection in Monroe, Gastonia home Home Inspections in Charlotte, Mooresville, Concord,...
  • Page:
  • 1
Time to create page: 0.194 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.