In pointing this fact out....Is it just a recommended upgrade as a possible safety hazard?
I mean the buyer is'nt required to replace the rails with new ones to meet the current standard? David |
Please Log in to join the conversation. |
|
Yes, I would identify as potential safety concern and recommend upgrade.
|
Please Log in to join the conversation.
Proudly providing home inspections services to Metro vancouver and the Fraser valley Area
A hospital bed is a parked taxi with the meter running. Groucho Marx |
|
The reality is most clients will not make this upgrade and making any more of it than it being a recommended upgrade due to safety would be unnecessary. Brian is dead on. Say that and you have addressed it correctly.
|
Please Log in to join the conversation.
Title: Home Inspection Peoria, IL
URL: www.aaintegrityhomeinspection.com |
|
Thanks for the feedback...
|
Please Log in to join the conversation. |
|
The seller is not required to fix anything. The buyer is not required to fix anything. Homes for sale do not have to meet current code or be brought up to current code.
Anything a home inspector puts in their report is ultimately a recommendation, regardless of what athority or technical reference they use to explain the defect. Hand and Guard rail spacing was developed so that babies bodies cannot fall through and their head act as a stopper and then strangle themselves. The extra 3/8 inch for stairs is because it is difficult to fit 3 spindles on a minimun tread depth. 2 fit nicely with 4 3/8 inch spacing. Call it out everytime. And while you are at it, don't foget to call out the oversized stair hand rails on almost every deck staircase. Handrails diminsons are defined in building code to about 2x2 inches square. 2x4s and 2x6a are oversized and not graspable. IRC 311.5.6.3 |
Please Log in to join the conversation.
Bruce Ramsey, ACI
|
|
Agree with others above.
Also, keep in mind that there are ways to improve the situation without replacing the spindles. A relatively simple method is installing glass (or plexiglass) panels. |
Please Log in to join the conversation.
Jeffrey R. Jonas
507.213.7468 This email address is being protected from spambots. You need JavaScript enabled to view it. FB: www.facebook.com/MN.Home.Inspector www.JRJConsultants.net www.OwatonnaHomeInspector.com www.MinnesotaCommercialBuildingInspections.com URL: www.owatonnahomeinspector.com Title: Critical Eye Property Inspections Description: Providing... |
|
|