Wasn't sure where to put this one.
I have never seen this set up before. I ran into a gas hot water heater. The home also had an indoor wood burner installed in the basement. The wood burner went right into the metal chimney. My question is this, is it ok for the gas water heater to also be exhausting into the same flue? |
Please Log in to join the conversation.
Square One Home Inspection
Square One Home Inspection proudly serves Green Lake, Fond du Lac, Dodge, Marquette, Columbia, Winnebago, and Waushara Counties. Complete home inspections, thermal imaging and Radon testing available. www.squareonehomeinspection.com Keywords : Fond du Lac Home Inspection,... |
|
Ian, I think it is ok. Very similar to a water heater venting into the chimney of a gas furnace.
|
Please Log in to join the conversation.
<b>Title:</b>
Orland Park Home Inspector
www.OrlandParkHomeInspections.com <b>Des:</b> Orland Park Home inspector performs home inspections in Orland Park, Tinley Park, New Lenox, Frankfort, & Palos Heights. 708-535-6057, 708-612-6679 <b>UPath:</b>... |
|
Consulted with some heating and plumbing guys on this. It is NOT Ok. The water heater cannot be vented into the flue with the wood burner.
|
Please Log in to join the conversation.
Square One Home Inspection
Square One Home Inspection proudly serves Green Lake, Fond du Lac, Dodge, Marquette, Columbia, Winnebago, and Waushara Counties. Complete home inspections, thermal imaging and Radon testing available. www.squareonehomeinspection.com Keywords : Fond du Lac Home Inspection,...
Last Edit: by Ian Niquette.
|
Ian, they have a couple of issues going on here,
The use of dissimilar materials is never recommended The gas vent should terminate either into a approved flue or the atmosphere in a approved manner The gas flue appears to have negative pitch on it What is that hanging in front of the stove vent, it probably is combustionable and may be too close (there should be a data plate on the stove) Have a great day Tim |
|
Please Log in to join the conversation.
link:
www.timshomeinspections.com/
page title:TIMS HOME INSPECTIONS description: Maryland Home Inspector providing inspection services in western Maryland, and the surrounding ares which include Washington, Frederick, Allegheny counties and some areas of Pennsylvania keywords:licensed home... |
|
What is the reason Ian? Is it different than the water heater venting into the flue of a gas furnace? |
Please Log in to join the conversation.
<b>Title:</b>
Orland Park Home Inspector
www.OrlandParkHomeInspections.com <b>Des:</b> Orland Park Home inspector performs home inspections in Orland Park, Tinley Park, New Lenox, Frankfort, & Palos Heights. 708-535-6057, 708-612-6679 <b>UPath:</b>... |
Michael, what you should see is the gas furnace vent connecting to the vertical flue with the water heater connecting to the vertical flue with the smaller vent located above the larger, they should not be tied together, unless the manufacturers installation directions say otherwise Have a great day Tim |
|
Please Log in to join the conversation.
link:
www.timshomeinspections.com/
page title:TIMS HOME INSPECTIONS description: Maryland Home Inspector providing inspection services in western Maryland, and the surrounding ares which include Washington, Frederick, Allegheny counties and some areas of Pennsylvania keywords:licensed home... |