• 888-750-4777
  • This email address is being protected from spambots. You need JavaScript enabled to view it.
Welcome, Guest
Username: Password: Remember me
  • Page:
  • 1
  • 2

TOPIC: Weeps/Back flow and electrical.

Weeps/Back flow and electrical. 15 years 10 months ago #5541

Home was built in 2003.

No visible weeps at 1st and 2nd floor veneer.

Home had a water back up pump with no back flow device. (When was this required) I have the same set up and the city made the plumber install.

Homes sub panel connections at the main were just squeezed in at the main lugs.

Any thoughts on the weeps and water back up.
Attachments:

Please Log in to join the conversation.

Home Safe Home Inspections
Link Url: Cleveland Home Inspector - www.hshinspections.net/
Body:Performing Home Inspections in Cleveland, Parma, Brecksville, Broadview Heights, North Royalton, Strongsville and surrounding areas.
Keywords:Parma,Broadview...

Re: Weeps/Back flow and electrical. 15 years 10 months ago #5542

Main had recalled Sq. D AFCI and here is the photo of the improper sub panel. No isolation and no breaker in main or sub.

Attachments:

Please Log in to join the conversation.

Home Safe Home Inspections
Link Url: Cleveland Home Inspector - www.hshinspections.net/
Body:Performing Home Inspections in Cleveland, Parma, Brecksville, Broadview Heights, North Royalton, Strongsville and surrounding areas.
Keywords:Parma,Broadview...

Re: Weeps/Back flow and electrical. 15 years 10 months ago #5543

  • James Levy
  • James Levy's Avatar
  • Offline
  • Platinum Member
  • Platinum Member
  • NJ#24GI00101400, FL # HI7765
  • Posts: 872
  • Thank you received: 0
Man! There is a whole host of pain and suffering with this installation. Aside from the things that you stated, the neutrals and grounds are not separated in the sub., there are two neutrals on one terminal in the main, no bushing on the sub feeder. :o The only good thing is the main is a SQ-D QO panel. ;D

Please Log in to join the conversation.

www.homespectllc.com
Homespect LLC
Home and commercial Inspections in Medford, Mount Laurel, Cherry Hill, Voorhees, Marlton NJ, and the surrounding areas.

Re: Weeps/Back flow and electrical. 15 years 10 months ago #5544

  • James Levy
  • James Levy's Avatar
  • Offline
  • Platinum Member
  • Platinum Member
  • NJ#24GI00101400, FL # HI7765
  • Posts: 872
  • Thank you received: 0
Also the subs neutral/groundbar looks bonded to the cabinet!

Please Log in to join the conversation.

www.homespectllc.com
Homespect LLC
Home and commercial Inspections in Medford, Mount Laurel, Cherry Hill, Voorhees, Marlton NJ, and the surrounding areas.

Re: Weeps/Back flow and electrical. 15 years 10 months ago #5546

Drew

I use this illustration in my reports when I see the doubled neutrals.
The sub looks like either a home owner or a not very qualified electrician install. I deffered the whole mess to a specialist.

My buyer who seemed more concerned with new floors as he spent most of his time with the flooring contractor. (Floors were in good condition) And his 2 or 3 year old kept distracting him when he did manage to listen to me after he arrived 20 minutes late then had to use the bathroom for 5 minutes.

I made notes about the contractor and child in my conditions during inspection areas.
Attachments:

Please Log in to join the conversation.

Home Safe Home Inspections
Link Url: Cleveland Home Inspector - www.hshinspections.net/
Body:Performing Home Inspections in Cleveland, Parma, Brecksville, Broadview Heights, North Royalton, Strongsville and surrounding areas.
Keywords:Parma,Broadview...
Last Edit: by David Macy.

Re: Weeps/Back flow and electrical. 15 years 10 months ago #5810

Dave - wow, where to begin?

Electrical - "Run away!! Run away!"  Monty Python and the Holy Grail.  Good to defer to a specialist.  I also would have mentioned that it probably was not permitted or inspected by the county.
Sump - I have never seen copper plumbing used for sump pump discharge and have never seen a back flow preventer on one...  that is not done here, so I really can't comment.  Maybe we are really behind the times!
Weeps - that is a small area of brick.  I would think weeps would have been required in 2003, but here not there.  Weeps are good period.  I always report the lack of weep holes and don't care when a code requirement was put in place.
Buyer - you get all kinds.  I hate the ones who spend the whole inspection on the phone.  I end up ignoring them and finishing my inspection.  You were circumspect to note it on the report...

Please Log in to join the conversation.

Jay Markanich Real Estate Inspections, LLC
Based in Bristow, serving all of Northern Virginia
www.jaymarinspect.com
Northern Virginia Home Inspector
Festina Lente - Make Haste Slowly
  • Page:
  • 1
  • 2
Time to create page: 0.217 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.