• 888-750-4777
  • This email address is being protected from spambots. You need JavaScript enabled to view it.
Welcome, Guest
Username: Password: Remember me
  • Page:
  • 1

TOPIC: Proper connection at breakers?

Proper connection at breakers? 13 years 9 months ago #39159

  • Bert de Haan
  • Bert de Haan's Avatar Topic Author
  • Offline
  • Platinum Member
  • Platinum Member
  • If it is worth doing, it's worth doing well.
  • Posts: 741
  • Thank you received: 0
The connections don't look right to me.  All the wiring is under the screws of the breakers but it looks like they should be inserted between two plates and the screw tightening down on it.  I think that the picture shows that some of the wiring is only barely under the screw.  The metal plates may not be visible though.  The panel was a Commander.
Thanks
Attachments:

Please Log in to join the conversation.

Bert de Haan
www.KitchenerWaterlooHomeInspector.ca
Benchmark Home Inspection Services Kitchener-Wateroo and Guelph area Home Inspection
Serving Kitchener-Waterloo, Guelph, Orangeville, Mount Forest and surrounding areas.
Keywords: Kitchener-Waterloo home inspector, Guelph home inspection,...

Re: Proper connection at breakers? 13 years 5 months ago #41606

Bert,
I just saw this thread, and am surprised nobody has chimed in. You probably already have your answer from another source, but, here's mine anyway.

You are exactly correct. The conductor should be between the two cinch plates. Never directly under the screw (or next to it) for this style breaker. This is a giveaway of a Harry Homeowner install, or a really "wet-behind-the-ears" sparky wanna-be.

Please Log in to join the conversation.

Jeffrey R. Jonas
507.213.7468
This email address is being protected from spambots. You need JavaScript enabled to view it.

FB: www.facebook.com/MN.Home.Inspector

www.JRJConsultants.net
www.OwatonnaHomeInspector.com
www.MinnesotaCommercialBuildingInspections.com

URL: www.owatonnahomeinspector.com
Title: Critical Eye Property Inspections
Description: Providing...

Re: Proper connection at breakers? 13 years 5 months ago #41608

  • Bert de Haan
  • Bert de Haan's Avatar Topic Author
  • Offline
  • Platinum Member
  • Platinum Member
  • If it is worth doing, it's worth doing well.
  • Posts: 741
  • Thank you received: 0
As you may have guessed, I completed the report (and wrote this up) but thanks just the same for your comment.

Please Log in to join the conversation.

Bert de Haan
www.KitchenerWaterlooHomeInspector.ca
Benchmark Home Inspection Services Kitchener-Wateroo and Guelph area Home Inspection
Serving Kitchener-Waterloo, Guelph, Orangeville, Mount Forest and surrounding areas.
Keywords: Kitchener-Waterloo home inspector, Guelph home inspection,...
  • Page:
  • 1
Time to create page: 0.201 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.