• 888-750-4777
  • This email address is being protected from spambots. You need JavaScript enabled to view it.
Welcome, Guest
Username: Password: Remember me
  • Page:
  • 1
  • 2

TOPIC: Valley Flashing - Metal Roof (need some help please)

Re: Valley Flashing - Metal Roof (need some help please) 14 years 1 month ago #36037

I actually contacted a guy at metalroofingalliance.org (a great site by the way) who helped me out a lot.
Sent me a number of links showing proper valley flashing pieces and installation and told me they are called R or PBR panels.
They should have 4-6 minimum between the center of the valley flashing and the roof material (this had maybe 1-2") and there are a number of other issues as well.
The other problem, if I didn't mention it, is the entire underside of the roof sheathing is covered in foil bubble insulation so it's impossible to inspect any of the sheathing and also likely that any water leaking through would be directly channeled behind this impermeable material to other locations - not good.  It also explains why i didn't see much water damage to the framing members - it was probably running down to the end of the roof pitch and leaking in elsewhere (like the ceiling inside the house and garage that the guy was repairing!)

Please Log in to join the conversation.

Robert Decker
Hawkeye Residential Inspections, LLC
Iowa City, IA
This email address is being protected from spambots. You need JavaScript enabled to view it.
www.iowacityhomeinspections.com
  • Page:
  • 1
  • 2
Time to create page: 0.172 seconds
© 2004-2024 Home Inspector Pro Inc. All Rights Reserved.